Xycd60 Manual Upd

The is a dual-function battery controller module designed for DC 6V–60V systems. It acts as an automated switch to protect lead-acid or lithium batteries from overcharging and over-discharging by managing the connection between a power source (charger), the battery, and the load. Core Specifications Voltage Range: DC 6V to 60V.

battery charge controller XY-CD60L for lithium battery CD60L

Turn on ( ON ) to shut down the display after 5-10 minutes of inactivity. 5. Wiring and Installation xycd60 manual

For the most detailed, up‑to‑date information, refer to the manufacturer’s documentation.

| Battery Type / Voltage | Upper Limit (UP, overcharge) | Lower Limit (dn, cut‑off) | | :--------------------- | :--------------------------- | :------------------------- | | 12V Lead‑Acid (AGM/GEL) | 14.4 V – 14.7 V | 10.5 V – 11.0 V | | 12V LiFePO₄ | 14.4 V – 14.6 V | 10.0 V – 11.0 V | | 24V Lead‑Acid | 28.8 V – 29.4 V | 21.0 V – 22.0 V | | 48V Lead‑Acid | 57.6 V – 58.8 V | 42.0 V – 44.0 V | The is a dual-function battery controller module designed

: Although the XY‑CD60 can measure up to 60 V, it is designed for 48 V systems (maximum) because a fully charged 48 V lead‑acid battery can reach approximately 60 V. For 60 V systems, consider the XY‑CD60L variant or an alternative module.

Protects against over-discharge (undervoltage). The relay stays closed to power the load until the battery hits the lower limit ( dn ), at which point it disconnects to prevent battery damage. Interesting Technical Highlights battery charge controller XY-CD60L for lithium battery CD60L

When the battery voltage rises to or exceeds the configured Upper Limit Voltage ( UP ), the relay turns OFF (opens the circuit) to halt charging and prevent over-voltage damage. 2. Discharging Mode (OUT) Designed to protect batteries from deep depletion by loads.